Home 2.0 Technical Specification

Technical specification for the Hypervolt Home 2.0 EV Charger

Product Information

Model: Hypervolt Home 2.0

Connection Capacity: Single Phase, 7kW AC

Charging Connector: Tethered, IEC 62196/Type 2 OR SAE J1772/Type 1

Tethered Cable Length (m): 5 / 7.5 / 10

Dimensions (mm): 328 (H) x 243 (W)  x 101(D) 

Mounting Type:  Wall/Pole mounted

Colour:  Ultra White/ Ultra Black / Space Grey

Weight: 5.2 Kg

Unit Material: ABS composite

Charging Protocol / Mode : Mode 3 (compliant with IEC 61851-1)

Connectivity

WiFi: Wi-Fi 802.11b/g/n @2.4 GHz 

Bluetooth: Adoption via bluetooth low energy

GPRS/3G/4G: Optional

Network Security: State-of-the-art Cryptography Engine for fast and secure WLAN Connections with 256-Bit Encryption.  

App: Charger control functions via the Hypervolt app.

Electrical Properties

Rated supply voltage: 230V AC – Single Phase  (± 10% AC) 

Rated power: 7.4 kW 

Output supply: AC 230V 7.4 kW Single Phase 

(Note: May vary based on vehicle make and model as well as electrical installation setup.) 

Mains Frequency: 50 Hz

Rated impulse withstands voltage: 4000V 

Rated peak withstands current: 1000A @ 1ms

Energy Monitoring: Power and energy monitoring via. MID grade meter.

Rating against shock: Class I Equipment 

Type of system earthing: TN-C-S & TN-S (PEN Fault Protection) or TT

Electromagnet Compatibility (EMC): Classification Type B 

Standards and Compliance

EMC Compliance: EN 61000-6-3:2006, EN 61000-6-2:2019

Safety Compliance: Low Voltage Directive (LVD) 2014/35/EU, EN 60950-1:2006 + A11 + A1, EN 60950-22:2006

EV Charging Compliance: Fully compliant with Amendment 1 of BS7671:2018. EN 61851-1:2019, EN 61851-21:2002, EN 61851-22:2002, IEC 62196-1, IEC 61851-1, BS 7671:2018 + A1:2020.

Environment 

Operating Temperature: -25 to 40 °C

Operating Humidity: Up to 95% RH, non-condensing

Environmental Protection:  IP54

Pollution degree: 3

Maximum Altitude Level: 2000m 

Protection

Built in RCD: Internal 6mA DC ground fault current detection (compliant with BS 7671:2018). 

Built in PEN Fault: Comes with integrated PEN fault protection compliant with Amendment 2 of BS7671:2018.

Current Limit: Power and energy monitoring as standard; optional MID grade metering is available.

Overcurrent protection: Upstream circuit breaker (not supplied)

Mechanical impact protection: IK08

Features

Status Indication/HMI: Multi-colour LED ring along the side of the enclosure and via the logo on the front of the enclosure. 

Charging modes: Eco, Super Eco and Boost

Additional

Access: Non-restricted 

Use: Can be operated by ordinary people. (Keep clear of children / the unit should only be opened for servicing and repairs which should be conducted by Hypervolt approved personnel only, please see page 3 for safety notice).